国产成人无码区在线观看,亚洲成aⅴ人的天堂在线观看女人,chinese少妇偷,国产爽死你个荡货h粗暴视频

MBB AC Synchronous Servo Control System


MBB servo system adopts AC synchronous permanent magnet servo motor. The system has convenient control and high control precision. The main advantages of permanent magnet synchronous motor are: ①Accuracy, closed-loop control of position, speed and torque; ②Rotation speed, good high-speed performance, general The rated speed can reach 2000-3500 rpm; ③Adaptability: strong anti-overload capability, can withstand loads three times the rated torque, especially suitable for occasions with instantaneous load fluctuations and fast start requirements; ④Stable speed regulation, no rotation Torque pulsation, low noise and vibration.
Several advantages of MBB AC synchronous servo control system:
1. MBB high-speed servo system, the limit times of opening and closing the door can reach 12,000 times within 24 hours, which meets the requirements of continuous high-frequency operation of isolation doors in the field of automation equipment.
2. MBB AC synchronous servo has built-in multi-turn absolute encoder, the whole process absolute value limit, intelligent overshoot protection.
3. AI situational pure Chinese and English intelligent dialogue man-machine interface, easy to debug and set limits.
4. The door machine model adopts rare earth permanent magnet AC synchronous motor, three closed loops of current, speed and position. Low noise, high speed and high energy efficiency; the built-in anti-electric braking method can accurately control the actual limit.
5. The control system has the function of fast start and slow stop, and the anti-collision protection is provided with anti-collision and slow-back height and speed. AGV car interconnection.
6. The reducer adopts a reducer, and the worm gear reducer can realize self-locking, and the service life of the round trip is 300,000-400,000 times.
7. The structure of the planetary reducer is relatively compact, the return clearance is small, the precision is high, the service life is very long, and the rated output torque can be made large. The same 0.75KW motor, with a planetary reducer with a speed ratio of 15, has a rated output torque of 33.85N. /m, the round-trip service life is 1.8 million times.
8. The hyperboloid reducer has good working stability, and the bending strength and contact strength of the gear teeth are high, so the noise is low, the service life is long, and the round-trip service life is 1.5 million times.
9. In the case of relatively low temperature, with antifreeze function, the system can automatically run the interval time/number of times according to the temperature change in severe cold areas.

Technical parameters of MBB AC synchronous servo G series
Basic parameters MBB-SG650 MBB-SG750 MBB-SG1000 MBB-SG1500 MBB-SG2000
Motor Power 650W 750W 1000W 1500W 2000W
System Configuration MBB-G00 MBB-G00 MBB-G00 MBB-G02 MBB-G02
voltage AC220V AC220V AC220V AC220V AC220V
Reducer configuration Turbo/Hyperbolic/Planetary Turbo/Hyperbolic/Planetary Turbo/Hyperbolic/Planetary Turbo/Hyperbolic/Planetary Turbo/Hyperbolic/Planetary
Reducer model NMRV050 NMRV050 NMRV050 NMRV063 NMRV063
Reducer speed ratio 1:20.5/15 1:20.5/15 1:20.5/15 1:30 1:30
Servo motor rated speed 3500rpm 3500rpm 3000rpm 3000rpm 3000rpm
Servo motor Max torque (instantaneous overload) 6N.m 7.1N.m 12N.m 18N.m 22N.m
Servo motor IP rating IP65 IP65 IP65 IP65 IP65
Working temperature -25℃-60℃ -25℃-60℃ -25℃-60℃ -25℃-60℃ -25℃-60℃
Encoder configuration Multi-turn absolute value Multi-turn absolute value Multi-turn absolute value Multi-turn absolute value Multi-turn absolute value
Brake (brake) method External Brake / Internal Brake External Brake / Internal Brake External Brake / Internal Brake External Brake / Internal Brake External Brake / Internal Brake
Daily Max running times (times) 8000-10000 8000-10000 8000-10000 8000-10000 8000-10000
 
MBB AC synchronous servo G series control and display function
Control box material series plastic case/iron case/stainless steel plastic case/iron case/stainless steel plastic case/iron case/stainless steel plastic case/iron case/stainless steel plastic case/iron case/stainless steel
顯示 Touch screen standard / digital tube Touch screen standard / digital tube Touch screen standard / digital tube Touch screen standard / digital tube Touch screen standard / digital tube
Door opening speed setting interval (revolution) 1-3500 1-3500 1-3000 1-3000 1-3000
Closing speed setting interval (revolution) 1-3500 1-3500 1-3000 1-3000 1-3000
Auto-close delay time (seconds) 1- at will 1- at will 1- at will 1- at will 1- at will
Anti-collision and slow back function Standard Standard Standard Standard Standard
Slow start and slow stop function Standard Standard Standard Standard Standard
Operating status display selection Standard Standard Standard Standard Standard
Fault digital prompt Standard Standard Standard Standard Standard
One-click basic troubleshooting function Standard Standard Standard Standard Standard
Statistics Standard Standard Standard Standard Standard
Overload warning display Standard Standard Standard Standard Standard
Voltage real-time monitoring display Standard Standard Standard Standard Standard
Current real-time monitoring display Standard Standard Standard Standard Standard
Motor forward and reverse parameter settings Standard Standard Standard Standard Standard
Timed automatic power-off parameter setting (energy saving) Standard Standard Standard Standard Standard
Autorun with default parameters Standard Standard Standard Standard Standard
Anti-freeze shake function Standard Standard Standard Standard Standard
Motor system automatic matching Standard Standard Standard Standard Standard
 
MBB AC synchronous servo G series system and interface function
Radar door open signal 1 input Standard Standard Standard Standard Standard
Infrared safety protection signal 1 input Standard Standard Standard Standard Standard
One key switch interface Standard Standard Standard Standard Standard
Rapid rebound Standard Standard Standard Standard Standard
Automatic full door open signal input Standard Standard Standard Standard Standard
Interlock input Standard Standard Standard Standard Standard
Fault output Standard Standard Standard Standard Standard
Door stop status signal output Standard Standard Standard Standard Standard
Door running state process output Standard Standard Standard Standard Standard
Door closed in place status output Standard Standard Standard Standard Standard
Door open position status output Standard Standard Standard Standard Standard
Manual/automatic switching input Standard Standard Standard Standard Standard
Emergency stop input Standard Standard Standard Standard Standard
Supported limit types No limit required No limit required No limit required No limit required No limit required